MRI prostate contouring is not impaired by the use of a radiotherapy image acquisition set-up. An intra- and inter-observer paired comparative analysis with diagnostic set-up images

Fecha de publicación: Fecha Ahead of Print:

Autores

  • Maria Del Rosario Pastor Juan

    Autor

  • Ignacio Andres Garcia

    Autor

  • Lorena Lopez Martinez

    Autor

  • Veronica Lopez Honrubia

    Autor

  • Maria Isabel Tercero Azorin

    Autor

  • Mar Sevillano Capellan

    Autor

  • Elena Lozano Setién

    Autor

  • Roberto Berenguer Serrano

    Autor

  • Susana Castro Larefors

    Autor

  • Maria Magdalena Marti Laosa

    Autor

  • Francisca Martinez Terol

    Autor

Autores externos

  • Jimenez-Jimenez, E
  • Rovirosa, A
  • Roche, O
  • Arenas, M

Abstract

Purpose. - The use of MRI for radiotherapy planning purposes is growing but image acquisition using radiotherapy set-ups has impaired image quality. Whether differences in image acquisition set-up could modify organ contouring has not been evaluated. Therefore, we aimed to evaluate differences in contouring between paired of image sets that were acquired in the same scanning session using different parameters. Material and methods. - Ten patients underwent RT treatment planning with MRI co-registration. MRI was carried out using two different set-ups during the same session, MRI radiotherapy set-ups and MRI diagnostic set-ups. Prostates and rectums were retrospectively contoured in both image sets by 5 radiation oncologists and 4 radiologists. Intra-observer analysis was carried out comparing organ volumes, the Dice coefficient and hausdorff distance values between two contouring rounds. Inter-observer analysis was carried out by comparing individual contours to a generated STAPLE consensus contour, which is considered the gold standard reference. Results. - No significant differences were observed between MRI acquisition set-ups. Significant differences were observed for the dice and hausdorff parameters, comparing individual contours to the STAPLE consensus contour, when analysing diagnostic images between rounds, although raw values were similar. Conclusion. - Prostate and rectum contours did not differ significantly when using diagnostic or radiotherapy MRI acquisition set-ups. (C) 2020 Societe francaise de radiotherapie oncologique (SFRO). Published by Elsevier Masson SAS. All rights reserved.

Datos de la publicación

ISSN/ISSNe:
1278-3218, 1769-6658

Cancer Radiotherapie  ELSEVIER

Tipo:
Article
Páginas:
107-113
PubMed:
33423967
Enlace a otro recurso:
www.scopus.com

Citas Recibidas en Web of Science: 2

Citas Recibidas en Scopus: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • MRI; Intra-observer; Inter-observer; Contournage

Compartir