Dosimetrical and geometrical parameters in single-fraction lattice radiotherapy for the treatment of bulky tumors: Insights from initial clinical experience

Fecha de publicación: Fecha Ahead of Print:

Autores

Autores externos

  • Prado, A
  • Martí, J
  • Zucca, D
  • de la Casa, MA
  • García, J
  • Alonso, L
  • Martínez, A
  • Montero, A
  • Rubio, C
  • Fernández-Letón, P

Abstract

Purpose This study aims to investigate lattice radiotherapy (LRT) for bulky tumor in 10 patients, analyzing geometrical and dosimetrical parameters and correlations among variables. Methods Patients were prescribed a single-fraction of 18 Gy to 50 % of each spherical vertex (1.5 cm diameter). Vertices were arranged in equidistant planes forming a triangular pattern. Center-to-center distance (Dc-c) between vertices was varied from 4 to 5 cm. A new method for calculating the valley-to-peak dose ratio (VPDR) was proposed and compared to other two from existing literature. GTV volumes (V-GTV), vertex number (N-vert), low-dose related parameters and vertex D-99%, D-50%, and D-1% were recorded. Beam-on time and Monitor Units (MU) were also evaluated. Correlations were assessed using Spearman's coefficient, with significant differences analyzed using Mann-Whitney U test. Results Tumor volumes ranged from 417 to 3615 cm(3). Median vertex number was 14.5 (IQR:11.3-17.8). VPDR ranged from 0.16 to 0.28. Median D-99% spanned from 10.0 to 13.7 Gy, median D-50% exceeded 18.0 Gy, and median D-1% surpassed 23.3 Gy. Periphery dose remained under 4.0 Gy. Plans exhibited high modulation, with median beam-on time and MU of 8.8 min (IQR:8.2-10.1) and 13,069 MU (IQR:11574-13639). Significant correlations were found between N-vert and V-GTV (p < 0.01), MU (p < 0.02) and beam-on time (p < 0.01) and between Dc-c and two VPDR definitions (p < 0.02) and periphery dose (p < 0.01). Significant differences were observed among the three valley dose definitions (p < 0.01) and the three peak dose definitions (p < 0.01). Conclusions Reporting geometrical and dosimetrical parameters in LRT is crucial, alongside the need for unified definitions of valley and peak doses.

Datos de la publicación

ISSN/ISSNe:
1120-1797, 1724-191X

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS  ELSEVIER SCI LTD

Tipo:
Article
Páginas:
103408-103408
PubMed:
38889590

Citas Recibidas en Web of Science: 2

Citas Recibidas en Scopus: 2

Documentos

  • No hay documentos

Métricas

Filiaciones mostrar / ocultar

Keywords

  • Lattice radiotherapy (LRT); Bulky tumors treatment; Lattice array design; Valley-to-peak dose ratio